Design Accidental Load for Explosion Resistant Design
Sirous Yasseri , Hamid Bahai
PhD Brunel University
Abstract:   (459 Views)
The accidental release and ignition of flammable vapours in petrochemical facilities generate overpressure and drag load which can impact the safety of installation and people. The intensity of the blast loads depends on many influencing factors including congestion, geometry, type & amount of fuel, leak size, and points of ignition among others. Given the stochastic nature of these parameters, it is obvious that the design for accidental load must be determined using a probabilistic method. This paper discusses a methodology known as “explosion exceedance diagram” and draws on recent developments in vapour cloud explosion research to determine the design accidental load (DAL). A case study demonstrates the application of the method.
Keywords: Keyword: Explosion, Design accidental load, DAL, Blast on Offshore Platforms
Full-Text [PDF 615 kb]   (208 Downloads)    
Type of Study: Research | Subject: Offshore Engineering
Received: 2017/09/4 | Accepted: 2017/12/24 | Published: 2018/01/23
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Yasseri S, Bahai H. Design Accidental Load for Explosion Resistant Design. ijcoe. 2017; 1 (3) :41-49
URL: http://ijcoe.org/article-1-55-en.html


Volume 1, Issue 3 (12-2017) Back to browse issues page
International Journal of Coastal and Offshore Engineering International Journal of Coastal and Offshore Engineering
Persian site map - English site map - Created in 0.05 seconds with 31 queries by YEKTAWEB 3647